Floor simply process done, it can be used as a geothermal floor.
The bad: be afraid of water, feet are afraid of the tide is hard, rigid, after you cannot repair the damage.
First, you can use the keel laying
Disadvantages: low thermal conductivity; expansive, receptors and environmental impact; not wear-resistant, easy to install deformation, inconvenience (erection keel, costly and compressed the indoor space height), the price is high, difficult to maintain; on wood consumption.
Both have the advantage of bamboo flooring: look bright and clean, bright, fresh, natural, smooth texture and delicate, high surface hardness coefficient; and a parquet strengths: excellent stability, pavement and convenient, suitable for large pavement, cost-saving. It also has a foot comfort, flexibility, in line with the elderly and children on safety requirements and warm in winter and cool in summer, moisture-proof coating, solid and resistant, long life and other advantages.
(2) parquet feet feeling good; heat conduction is slow; good thermal insulation properties; parquet variant slots on the back of favourable to the air circulation, increase heat utilization and also reduce noise.
Advantages: soft, smooth surface geometry size, quality and stability; floor non-toxic, anti-mildew, featuring insect borers; flame-resistant, wear-resistant; warm in winter and cool in summer, the price between solid wood flooring, and composite wood flooring.
Geothermal heating floor also known as low-temperature hot water radiant heating radiant floor, is a kind of the Interior of the ground for heating systems. It is the entire ground floor as a heat sink in the laying of the pipeline within the structural layer, fill the pipeline through to 60 ° c, low temperature hot water heating of floor concrete layer so that the surface temperature at 26 degrees centigrade or so, so that people feel warm and comfortable. Indoor temperature drop, giving the foot warm head cold feeling, meet the optimum physiological Sciences. It saves room in the efficient use of space, and energy conservation. Use of low temperature hot water floor heating temperature of feel than the actual temperature higher than 2 ° c to 4 ° c. It conforms to the "household metering, room thermostat" requirements, the home is to stop the heating, small population may be some activity room heating, off and no one room of the valve. Long service life, its use of aluminum-plastic composite pipe is the world's recognized service life of 50 years of material. In addition, this kind of heating also has reduced floor noise, sanitation, heat source select range, suitable for rebuilding. Measure the real geothermal floor is need many specific technical parameters. First of all, it must have very good heat resistance. Geothermal floor in material selection is very particular about the strictly selected those wood density to meet the requirements of special materials. Floor thickness in 6.5 — 8.5 mm (the thickness of the geothermal floor standard), ensure that the floor with good breathability and thermal dissipation. The second feature is the heat tolerance. Geothermal floor finished in fact have a little taste of have. In its production process to go through a rigorous four cycles. Namely: floor hot water at 100 ° c and cook for 4 hours in 60 ° c in the oven → in baking 20 hours → 100 ℃ hot water boiled in 3 hours → minus 20 ° c freezer 2 hours. And from the fourth floor, ensure the long-term high temperature, no crack, no degumming, resistance to humidity, no distortion, no anti warped. The last point is green. Health and safety is a fundamental requirement for geothermal floor. Product should comply with international environmental standards (European environmental standards as E1; Japan environmental standards for F1; formaldehyde emission levels lower than in China 0.12mg/m3 is equivalent to the international standard). Because specialized geothermal floor prices are more expensive, the average wage earnings hopes to find a cost effective and meet the requirements of the products at great prices. For share several alternatives. Suitable for floor heating systems with wood floors there are the following: first, the 7-8 mm thick wood flooring, with 2 to 3 mm foam cushion; the second, 8 to 12 mm thick or more three-layer parquet, use 2 to 3 mm foam cushion; third, 8 mm thick mosaic parquet floor or mosaic parquet floor, with 2 to 3 mm foam cushion; fourth, 10 to 12 mm thick solid wood flat-floor; fifth, length, width and height are less than 60 x 60 x 15 mm solid wood flooring, best piece together is 200 × 40 × 10 mm specifications of floor, in the construction of the spell square or Chevron make it uniform thermal deformation. In short, geothermal heating of wood flooring choices to master the following principle: the wood floor dimensions to stability, better heat stability, low moisture content, so that the floor heating is not easy to facilitate heat deformation; and conduction, cushion material should not be too thick; not suitable for floor size, suitable for thin and thick should not narrow width, to the benefit of resistance to deformation and heat requirements.
Disadvantage: the same Bamboo flooring
(4) cork flooring: Cork is growth in the Eastern Mediterranean coast and the Qinling Mountains region of oak and cork oak is the raw material of bark, cork flooring is referred to as a "floor" of pyramid consumption. Simply put, cork flooring is Cork granules and elastic adhesive, using special techniques and equipment for the processing of a surface paving materials, General 3.2 mm to 4 mm of thickness. Cork Flooring density is divided into three levels 400kg-450kg/m3; 450kg-500kg/m3; greater than 500kg/m3. Generally use low density, low density as selected because it has better flexibility, insulation, sound absorption, vibration, etc.
You only need to process done, it can be used as a geothermal floor.
Because of the advantages of geothermal heating, are more and more users, more and more widely applied. In China the ratio of Northern geothermal heating increases every year. Dalian and Qingdao geothermal heating ratio is close to or exceed the ordinary heating rates. With the development of science, the types of geothermal energy is constantly increasing, such as hot water as the medium of floor heating, heating cable for electric heat medium to warm to electrothermal film for electric heat media film to warm. In
Compared to the cold Northeast and North China, due to the heating cost reasons, the use of hot water as the medium of floor heating, individual users also have the use of gas heating their small boiler to boost geothermal. Currently, geothermal energy is no longer a "patent" to the North, especially in the South, some of the more developed regions, and also do a geothermal. For example, Shanghai, Nanjing, Wuhan, Hangzhou, electric heating is also increasing. In Guizhou province, Jiangxi some electric floor heating. South of the user can select at home all regions use a heating system, but also can select part of the region (such as bedroom, Hall). Current electric heating system has been in Europe, North America's vast region is widely accepted and recognized; along with the improvement of living standards, such emerging heating methods in the country also has a growing number of applications.The structure can be divided into: three-layer parquet to plywood as substrate for parquet;
To reduce losses and increase geothermal energy of heat transfer performance of floor, geothermal heating surface use floor thickness should not exceed 12. Flooring of common specifications for 8?, in the specifications for the most suitable on laminate flooring. The parquet thickness should be in the following 12?, best 10?, at the same time, the geothermal dedicated parquet must back saw resistant variant slot, lower floor variant degrees in order to guarantee the quality of the floor.
In all types of flooring, three tier or parquet, laminate flooring is suitable for geothermal. These two types of floor stability, variant of small, high temperature for a long time are quality problems, and solid wood flooring and Bamboo flooring deformation degree, not suitable for geothermal.
Disadvantages: feet are relatively hard, skin styles less; durability is poor, the Sun and humidity will be out? stratification.
Disadvantages: not wear, suits limited, with a certain amount of formaldehyde, etc.
6. the use of geothermal floor of misleading
No comments: